UniversityEssayServices

A planar scintigraphy imaging system (assume a 2-D system) is set up with the collimator as shown in Figure P8.5.

Figure P8.5 System setup for Problem 8.15.

Three compartments P, Q, and R mimick three different tissues, and have attenuations μP = 0, μQ = 0, and μR = 0.1 mm−1, respectively. Assume δ ≈ 0 mm. N0 atoms of radionuclide A ( = 3 hours) were put uniformly in compartment P, and  atoms of radionuclide B (= 6 hours) were put uniformly in compartment Q.

(a) Compute the projection φ(x) [units of photons s−1 cm−1] at 1) time t = 0 and 2) time t = .

(b) Determine the time tmax at which the absolute signal difference |φ(5) − φ(−5)| is maximum .

(c) What is the collimator efficiency and resolution?

(d) What is the absolute signal difference at time t = 3 hours incorporating collimator efficiency.

(e) What is the width of compartment P in the final image? (Assume the system resolution is dominated by the collimator resolution.)

Found something interesting ?

• On-time delivery guarantee
• PhD-level professional writers
• Free Plagiarism Report

• 100% money-back guarantee
• Absolute Privacy & Confidentiality
• High Quality custom-written papers

Related Model Questions

Feel free to peruse our college and university model questions. If any our our assignment tasks interests you, click to place your order. Every paper is written by our professional essay writers from scratch to avoid plagiarism. We guarantee highest quality of work besides delivering your paper on time.

Sales Offer

Coupon Code: SAVE25 to claim 25% special special discount
SAVE